OUTLET 240v Compact 240v Connection

 

*DO NOT USE THIS CONNECTION AS A STANDARD HOOKUP CONNECTION. THIS IS A POWER OUT SUPPLY TO POWER UP AN EXTERNAL AWNING. This connection must be made live by a 240v supply from the van

 

One of the only compact BS rated IP67, if not only, on the UK market

 

We are the UK distributor for Phillipi Marine products and these can only be found through us

• IP67

• POWER OUTLET CONNECTION

 

*This connection is an OUTLET connection to allow hookup TO an external source such as an awning. The male pins are on the lead and not the surface mounted connection which has female, protected live pins

 

• 16A rating

• Rated 400v Feed, polarity + connection would still be using UK 3 Pole twin + earth arctic cable with a UK commando at the main hookup side but with a neater connection to the van (not supplied)

 

British BS EN 60529:1992, European IEC 60509:1989 IP67 | Protected caps from immersion in water with a depth of up to 1 meter (or 3.3 feet) for up to 30 mins

  • Fitting Guide

    https://www.customveedubs.com/compact-ehu

    NOTE If wiring and powering from a UK domestic socket you must ensure the plug top is rated at 13A or below OR any dediated supply on a MCB is rated to 10A or less than 16A.  A 32A ring main will share 16A across the ring which can max out the load.  If in doubt speak to a local Electrician for further advice.

    This does not impact on UK campsites which have a 10A MCB feed

    Connection - a bad connection (pin not clean, screw not tight etc). This would cause the connection to be high resistance which would generate heat

    MCB – Change to a 10A dedicated feed to avoid maxing out at 16A even with a 13A fuse on the plug top. The actual current, where a BS 1362 fuse will blow, is about 1.66 times the rated value, so for a 13A fuse this will be 21.6A

    • To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. 
    • Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
    • The end user must take suitable safety measures to ensure that the connector cannot be disconnected accidentally.
    • Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. A 20mm electrical shroud must be used (SHROUD not supplied - if you are fitting anywhere that is not surface sealed this must be used)
    • To lock the cable connector to the connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).